The Ministry of the Interior, together with the Ministry of Education and Merit, has renewed the rules on fire safety in schools with the Decree of 31 March 2026, published in the Official Gazette no. 81 of the’8th April. This decree defines the new adjustment pathway for School buildings and school premises that have not yet completed the transposition of the legislation Fire prevention.

New deadlines for fire safety upgrades in schools

The provision Organise the tasks into two phases. The first requires the achievement of a minimum fire safety level to be certified with SCIA (Certified Notification of Commencement of Work). The second phase requires the completion of all interventions with works concluding by the end of 2027.

The decree does not replace the current technical regulations on occupational safety and systems. Instead, it introduces more precise deadlines for inspections, system maintenance, and the updating of emergency plans. This allows educational institutions to schedule activities over time and ensure a minimum level of safety from the outset. The aim of the decree is to guarantee the safety of students and staff, fostering a culture of active rather than reactive prevention.

Phase 1: Minimum fire safety adjustments and partial SCIA

Within nine months of the decree's publication, school buildings not yet compliant must present the SCIA "partial”provided for by Article 4 of DPR 151/2011. This document certifies the adoption of mandatory minimum fire prevention measures.

In the first phase of the fire safety compliance path in schools, the essential measures to be respected are those established by D.M. 26/08/1992. The first SCIA must certify the implementation of the following measures:

  • General Information;
  • Emergency lighting;
  • Sound diffusion system;
  • Alarm systems;
  • Fire extinguishers;
  • Safety signage;
  • Operating instructions.

Phase 2: completion of fire safety adaptations in schools by 2027

The second deadline is set for 31 December 2027. By this date, schools must complete all planned fire safety measures and submit the SCIA “final“, which certifies the Full fire safety compliance of the building.

The main measures to be taken to complete the fire safety compliance in schools include:

  • Fire load limitation I enter values compatible with the fire resistance of structures;
  • Removal of materials with lower fire reaction characteristics to which requests;
  • Verification of Compatibility between overcrowding and evacuation system, with a possible reduction in attendance;
  • Constant surveillance on operating conditions, accessibility and absence of material damage.

Fire safety training for staff and fire drills in schools

The decree provides for the Firefighter enhancement in schools, by increasing the number of workers responsible for fire prevention, firefighting, and emergency plan management.

Internal staff can be integrated with external figures. In the event of awarding a contract, the service must be assigned to operators with proven professional suitability and adequate economic-financial and technical-professional capacities, in compliance with the Legislative Decree 36/2023.

Tutto il personale incaricato deve frequentare il Firefighting training course type 3-FOR Annex III of D.M. 2 September 2021) and get the’Certificate of Technical Suitability.

Among the transitional arrangements, the decree provides for the carrying out of at least two additional fire drills per year, in addition to those already scheduled. Every surveillance and drill activity must be reported in the control register.

Irbema's sound evacuation system

Fire safety in schools compact 500 IRBEMA decree 2026
       Compact 500

Irbema S.r.l. is the exclusive distributor in Italy of 4Evac by Bosch, a brand specialising in sound diffusion systems for fire evacuation.

A Sound evacuation system (EVAC system) It has the task of reliably and intelligibly transmitting voice alarm messages, guiding people during an emergency. The system also supports public address functions, such as background music, public announcements and general paging. In the event of an alarm, emergency messages always have the highest priority.

The solution Compact 500 by 4Evac it is a voice alarm system contained in a single wall-mounted console, designed to be installed in the entrance area of the building, where it is easily accessible in the event of an emergency. The controls are intuitive and the Built-in microphone guarantees clear communication in all evacuation zones.

The main part of the system is the DA200 amplification module, which provides up to 200W of power its 100V constant voltage line. The Compact 500 is available in three configurable versions:

  • 200W over 2 channels (to serve 2 zones or guarantee redundant A/B line on a single zone);
  • 400W over 4 channels;
  • 600W over 6 channels, each 100W.

This is a solution certified well beyond the minimum requirements, quick to install and simple to manage via configuration software with IP30 protection rating. It fully complies with the standards EN54-16:2008, EN54-4:2006 and EN50130-4:2011 (CPR: 0560-CPR-152190001/00).

 
 
Fire safety in schools amplifier da200 irbema decree 2026
        DA200 amplifier module

Do you need more information? Contact our experts without obligation for advice on the most suitable fire protection solutions for your school.

📞 +39 039249121

📩 info@irbema.com

Thank you for contacting us!

We have received your message. We will reply as soon as possible.

Before leaving...

Leave us your contact details and we will contact you back for a free consultation